Display method | Non-display |
---|---|
Number of input channels | 2-channel |
Input specification | Thermocouple: K(CA), J(IC), E(CR), T(CC), B(PR), R(PR), S(PR), N(NN), C(TT), G(TT), L(IC), U(CC), Platinel II RTD: DPt100?, DPt50?, JPt100?, Cu100?, Cu50?, Nickel120? Analog: -60-60mV, 0-200mV, 0-1V, 1-5V, 0-5V, 0-10V, 0-20mA, 4-20mA |
Sampling cycle | 50ms(2-CH synchronous sampling) |
Power supply | 5VDC USB bus power |
Protection structure | IP20 |
Approval | @(CE) @(KC) |
Communication type | USB |
Protocol | Modbus RTU |
Display accuracy_RTD | ??t room temperature range (23????? : (PV ?0.3% or ?1?? select the higher one) ?1-digit ??ut of room temperature range : (PV ?0.5% or ?2?? select the higher one) ?1-digit |
Display accuracy_Thermocouple | ??t room temperature range (23????? : (PV ?0.3% or ?1?? select the higher one) ?1-digit ??ut of room temperature range : (PV ?0.5% or ?2?? select the higher one) ?1-digit |
Display accuracy_Analog | ??t room temperature range (23?????: ?0.3% F.S. ?1-digit ??ut of room temperature range: ?0.5% F.S. ?1-digit |
Insulation type | Double insulation or reinforced insulation |
Mounting type | DIN rail or panel mounting |
Accessories | USB 2.0 AB type cable: 1 (length: 1m) |
Environment_Ambient temperature | -10 to 50?? storage: -20 to 60??/td> |
Environment_Ambient humidity | 35 to 85% RH, storage: 35 to 85% RH |
Weight | Approx. 195g (approx. 140g) |